Chemqua Prime
2-component, water-thinnable epoxy primer
Product Description
Storage Conditions/Shelf Life
- 24 months from the date of manufacturing if stored properly in undamaged seal packaging, at a temperature between 5°C-30°C. It should be kept in a cool, well-ventilated area, away from heat, direct sunlight, sparks, and children.
Salient Features
- Easy and fast application
- Especially suitable for highly absorbent substrates
- Water-based and odourless.
- Very good bond strength over a wide temperature range
- Can apply on green concrete
Product Data
| Component | Description |
|---|---|
| Chemqua Prime [R] Resin | White liquid |
| Chemqua Prime [H] Hardener | Clear liquid |
Uses
- Concrete floors with moisture-related issues
- New and old concrete
- Slabs without a damp-proof membrane and a risk of rising moisture.
- Can be applied on green concrete, thus eliminating the. need to wait for 28 days after concrete casting.
Chemical Properties
| Property | Test Method | Value and Unit |
|---|---|---|
| Mixing Ratio (Chemqua Prime [R] : Chemqua Prime [H]) | — | 4:1 |
| Pot Life @ 30°C | CPI 1002 | 30–35 minutes |
| Surface Dry | CPI 1002 | 4–5 hours |
| Hard Dry [Open for Foot Traffic] | CPI 1002 | 24 hours |
| Coverage for 150–200 Micron Coat | CPI 1010 | 5–7 sqm/litre |
All Chemsol Products are recommended to be applied only by Approved Applicators and should be handled after using proper PPEs like Gloves, mask, goggles etc.
Method of Application
Application conditions

Substrate temperature: 10-40°C

Substrate moisture content: - It can be applied on green or damp concrete, provided there is no standing water/ponded water, but it is recommended to wait for 72 hours after casting the cement so as to allow the concrete to shrink, so that the cracks generated in concrete during shrinkage are not carried to the epoxy coating.

Relative humidity: 8o%max
Substrate Quality
Substrate Preparation
Mixing
Cleaning of Tools
Packing
Storage Conditions
Handling & Safety
*Disclaimer: The Information provided is based on our experience, thorough investigations & sophisticated testing methods, but due to the vast number of applications and usage methods, Chemsol Polymer Industries cannot accept responsibility of any kind for any particular result. It is the responsibility of the user to verify the suitability of the product for their end use and in accordance with the rules and regulations of that country/territory. All information provided pertaining to our products should be treated only as a guidance tool without any guarantee or warranty of any sort.
* All CPI test methods are our scientifically designed Internal test methods which can be shared upon request