Chemductive

4-component, self-leveling, electrostatic dissipative, epoxy-based flooring system.

Product Description

Chemductive is a four-component epoxy floor coating system formulated to impart electrostatic control properties to a cement or concrete floor. It offers attractive, durable, seamless floors with Electrostatic conductive protection.

Uses

  • especially recommended for areas that require a conductive surface. Application areas include;
  • Storage silos, testing laboratories.
  • Electronics manufacturing and maintenance
  • Data processing facilities, semiconductor assembly areas, etc.
  • Clean rooms, Aircraft hangars, pharmaceuticals etc.

Salient Features

  • Complies with general conducting requirements as per ANSI/ESD S20.20 standards.
  • Good mechanical and chemical resistance.
  • Easy application, durable.
  • Easy cleanability.
  • Constant conductivity readings over a prolonged period.
  • Available in various shades.

Product Data

Appearance / colour:Chemductive [R] Resin:Hazy black liquid
 Chemductive [H] Hardener:Transparent liquid
 conductive AggregateWhitish Powder
 pigmentColour paste

Storage conditions /shelf life

12 months from date of mfg. if stored properly in shelf life, undamaged seal packaging, at a temperature between 5 °C- 30 °C. It should be kept in a cool, well-ventilated area, away from heat, direct sunlight, sparks, and children.

Chemical Resistance

Excellent resistance is observed against distilled water, detergent solutions, alkalis, and acids.

Mechanical/Physical properties

Physical properties of Chemductive

PropertyTest MethodValue and Unit
Mixing RatioNAPre-weighed kit to cover 10-12 sq.m area @ 1000 micron thickness
FinishCPI* 1001Non porous, Smooth, Glossy
Pot Life @ 30 °CCPI 100230-35 minutes
Surface DryCPI 10023 Hours
Hard Dry [Open for foot traffic]CPI 100224 Hours
Full Cure [Vehicular Movement]CPI 100272 Hours

 

Mechanical properties

PropertyTest MethodValue and Unit
Compressive StrengthASTM C 579>600 Kg/cm²
Flexural StrengthASTM C 580>400 Kg/cm²
Tensile StrengthASTM C 307>200 Kg/cm²
Pull off Adhesion TestASTM D 4541Concrete Failure @ 18 Kg/cm²
Abrasion Resistance [Taber]ADTM D 406050 mg loss
Shore HardnessASTM D 2240D 80
Electrical ResistanceASTM F150104-106 Ω
Shelf Life12 months in original unopened container when stored between 5 °C – 40 °C

Method of Application

All Chemsol Products are recommended to be applied only by Approved Applicators and should be used after using proper PPE’s like Gloves, mask, goggles etc.

Substrate Quality

The CDS (clean, dry, sound) test must be conducted before the application of primer to the concrete substrate. The substrate must be free of all contaminants such as dirt, oil, grease, coatings, and surface treatments etc. If in doubt, apply a test area first.

Application conditions

Substrate temperature: 10-40°C

Substrate moisture content: - <5%

Relative humidity: 8o%max

Note: The substrate temperature must be at least 30 °C above the prevalent dew point temperature to reduce chances of condensation on the floor.

Substrate Preparation

Concrete substrates must be prepared mechanically using abrasive blast cleaning, scarifying, or grinding equipment to remove cement laitance and achieve an open-textured surface. Remove weak concrete and expose surface defects such as blowholes and voids. Repairs to the substrate, filling of blowholes/voids, and surface levelling must be carried out using appropriate products. Ensure that the dust, loose and friable material is completely removed from all surfaces by brush and vacuum before application of the product. The concrete substrate has to be primed and levelled with Chemprime/ Chembase 150 in order to achieve an even surface and to seal the porosities. Allow the primer to cure for 5-6 hours. After this, depending on the system selected, either apply a screed coat followed by fixing of high adhesion *Chemopper special grade copper tape/ or copper tape can even be directly applied on the primer by omitting the screed coat. The copper tape is then connected securely to the earthing points. Now apply a 2K conductive primer coat of *Aquaprime at a DFT of 90-110 microns. This is followed by the application of Chemductive Top Coat as per the guidelines below.
(Note: adhere to the curing schedule of Aquaprime conductive primer before application of topcoat.) *Refer to the method of statement for guidelines on fixing of copper tape. *refer TDS of Aquaprime

Application of Chemductive Top coat.

Pour the resin part in a 20L bucket and add colour paste to the resin and mix till a uniform colour is achieved. Add hardener to this mixture and stir continuously for 1minute until a homogeneous mass is obtained. Add aggregates to this mixture and continue stirring for a further 1 minute with a motorised cowls blade disperser stirrer until a uniform mix is obtained. Overmixing must be avoided to minimise air entrainment. Strictly do not use other type of stirrer as it can damage the structure of Antistats and adversely affect the conductivity.

Note that the mixture has a stipulated pot life, hence the laying should immediately commence after mixing the contents.

Pour the contents onto the floor and spread evenly with the help of a notch trowel, and then roll with a spike roller to de-air and to obtain a uniform thickness.

Curing Schedule

The epoxy curing reaction rate is temperature dependent. Refer the following table to know how quickly the floor can be brought to service
Temp. (°C)Foot trafficFull cure
10°C48 hours120 hours
20°C 36 hours96 hours
30°C24 hours72 hours

Cleaning of Tools

Clean all tools and application equipment with thinner EP140 immediately after use. Hardened and/or cured material can only be removed mechanically.

Packing

Chemductive Resin, Hardener, aggregates, and antistats are available in a pre-weighed kit which covers 10-12 sq.m area with an approximate thickness of 1mm.

Handling & Safety

Keep the containers tightly sealed when not in use. Avoid skin contact and inhalation of fumes (if any). While spraying it is advised to wear a mask. If it comes in contact with the body, wash affected parts with plenty of soap and water. In case of persistent irritation, contact a physician.

*Disclaimer: The Information provided is based on our experience, thorough investigations & sophisticated testing methodsbut due to the vast number of applications and usage methods, Chemsol Polymer Industries cannot accept responsibility of any kind for any particular result. It is the responsibility of the user to verify the suitability of the product for their end use, and in accordance with the rules and regulations of that country /territory. All information provided pertaining to our products should be treated only as guidance tool without any guarantee or warranty of any sorts.

* All CPI test methods are our scientifically designed internal test methods which can be shared upon request.