Floorchem 300 UV

2-component, high build, UV stable PU based floor coating system.

Product Description

Floorchem 300 UV is a 2-component, high-build, Aliphatic isocyanate-based PU floor coating system formulated for light-fast UV-resistant high-build floor coating applications with a roller. It offers excellent chemical and abrasion resistance and is primarily used for dust proofing the floor in light to medium traffic areas exposed to sunlight.

Uses

  • Ideal for interior and exterior seamless floors.
  • Can be used as a UV-resistant wear layer over deck coatings and non-slip coatings
  • It is suitable as a concrete sealer and top coat
  • Clean rooms, Aircraft hangars, pharmaceuticals etc.
  • Light Engineering, textile industries.
  • Laboratories, testing areas etc.

Chemical Resistance

Excellent resistance is observed against distilled water, detergent solutions, alkalis, and acids.

Product Data

Property Value and Unit
Colour White
Consistency Paste
Surface Dry 40–45 minutes
Water Resistance Excellent
 

Salient Features

  • Good mechanical and chemical resistance
  • Easy application, durable
  • Excellent adhesion to substrate
  • Good flow
  • Long Pot Life
  • Excellent abrasion resistance
  • Non-yellowing, high gloss and matt finish option

Mechanical/Physical properties

PropertyTest MethodValue and Unit
Mixing RatioNA1:1 [R:H]
FinishCPI* 1001Non-porous, Glossy/Matt
Pot Life @ 30°CCPI 100230 minutes
Surface DryCPI 10022 hours
Hard Dry [Open for Foot Traffic]CPI 10028 hours
Full Cure [Vehicular Movement]CPI 100248 hours

 

Mechanical Properties

PropertyTest MethodValue and Unit
Elongation at BreakASTM D 63830–40%
Pull-off Adhesion TestASTM D 4541Concrete Failure @ 18 Kg/cm²
Abrasion Resistance [Taber]ADTM D 406050 mg loss
Shelf Life12 months in original unopened container when stored between 5°C – 40°C

Method of Application

All Chemsol Products are recommended to be applied only by Approved Applicators and should be used after using proper PPE’s like Gloves, mask, goggles etc.

Application conditions

Substrate temperature: 10-40°C

Substrate moisture content: - <5%

Relative humidity: 8o%max

Note: The substrate temperature must be at least 30C above the prevalent dew point temperature to reduce chances of condensation on the floor.

Substrate Quality

The CDS (clean, dry, sound) test must be conducted before the application of primer to the concrete substrate. The substrate must be free of all contaminants such as dirt, oil, grease, coatings, and surface treatments, etc. If in doubt, apply a test area first.

Application of Floorchem 300UV Top coat.

Ensure that the underlying coat is thoroughly cured and is dust-free. Stir the resin part mechanically for 1 minute in order to disperse the pigments into the resin uniformly. Now add hardener and continue stirring for a further 2 minutes with a motorised helical paint stirrer until a uniform mix has been obtained. Pour the material on the floor and spread with a squeegee and roll with a short pile roller to obtain the desired finish.
*Refer surface preparation guidelines for application of primer Chembase 150.

Curing Schedule

This is a fast curing system. Refer the following table to know how quickly the floor can be brought to service
Temp. (°C)Foot trafficFull cure
10°C8 hours120 hours
20°C6 hours96 hours
30°C4 hours72 hours

Cleaning of Tools

Cleaning of Tools Clean all tools and application equipment with thinner PT 36 immediately after use. Hardened and/or cured material can only be removed mechanically.

Packing

Floorchem 300 is available in 1 and 4 liter pack of Resin and Hardener.

Handling & Safety

Keep the containers tightly sealed when not in use. Avoid skin contact and inhalation of fumes (if any). While spraying it is advised to wear a mask. If it comes in contact with the body, wash affected parts with plenty of soap and water. In case of persistent irritation, contact a physician.

*Disclaimer: The Information provided is based on our experience, thorough investigations & sophisticated testing methods, but due to the vast number of applications and usage methods, Chemsol Polymer Industries cannot accept responsibility of any kind for any particular result. It is the responsibility of the user to verify the suitability of the product for their end use and in accordance with the rules and regulations of that country /territory. All information provided pertaining to our products should be treated only as a guidance tool without any guarantee or warranty of any sorts.

* All CPI test methods are our scientifically designed internal test methods which can be shared upon request.